Section 11-3510. HEIGHT AND PENTHOUSES (WR)  


Latest version.
  •  

    3510.1 For the purposes of applying general zoning requirements of this title:

     

    (a) The WR-1, WR-7, and WR-8 zones shall be considered Residence zones and shall be subject to § 411;  and

     

    (b) The WR-2, WR-3, WR-4, WR-5, and WR-6 zones shall be considered Mixed Use or Commercial Zones and shall be subject to §§ 770.6-770.9 and 777.

    3510.2 In the WR zone, the point chosen for measurement of height shall conform to the other provisions of this title, except that the point may be on either a public or private street.

     

    3510.3A penthouse constructed in accordance with the provisions of § 411 may be erected to a height in excess of that permitted, but shall not exceed the height, as measured from the surface of the roof upon which the penthouse sits, in the following table:

     

    ZONE DISTRICT

    MAXIMUM PENTHOUSE HEIGHT

    MAXIMUM PENTHOUSE STORIES

    WR-1, WR-6

    Pursuant to §411.5

    Pursuant to §411.5

    WR-4, WR-5, WR-7

    12 ft. except 15 ft. for penthouse mechanical space

    1; second story permitted for penthouse mechanical space

    WR-8

    12 ft., except 18 ft. 6 in. for penthouse mechanical space

    1; second story permitted for penthouse mechanical space

    WR-3

    20 ft.

    1; second story permitted for penthouse mechanical space

    WR-2

    20 ft.

    1 plus mezzanine; second story permitted for penthouse mechanical space

     

     

authority

§ 1 of the Zoning Act of 1938, approved June 20, 1938 (52 Stat. 797, as amended; D.C. Official Code § 6-641.01 (2012 Repl.)).

source

Final Rulemaking published at 62 DCR 12168 (September 4, 2015); as amended by Final Rulemaking published at 63 DCR 390 (January 8, 2016).