Section 11-B327. GENERAL CONDITIONS FOR TRANSITION REGULATIONS  


Latest version.
  • 327.1The projections identified in the following table are permitted to encroach into any required height transition plane subject to the following limits:

     

    TABLE B § 329.1:  LIMITATIONS ON ENCROACHMENT INTO ANY REQUIRED HEIGHT TRANSITION PLANE

     

    PROJECTING ELEMENT

    LIMITATIONS

    Cornices and eaves

    Not to exceed 2 ft.

    Sills, leaders, belt courses, and similar ornamental or structural features

    Not to exceed 6 in.

    A balcony railing

    Not to exceed 4 ft.

    Skylights

    Not to exceed 4 ft.

    A chimney, smokestack, or flue

    No limit

    Spires

    No limit

    Towers, including towers erected from the ground

    No limit

    Domes, minarets, pinnacles, pergolas and similar architectural embellishments

    No limit

    327.2The projections and structures identified in the following table may encroach into any required buffer transition setback, up to the limits specified:

     

    TABLE B § 329.2:  LIMITATIONS ON ENCROACHMENT INTO ANY REQUIRED BUFFER TRANSITION SETBACK

     

    PROJECTING ELEMENT

    LIMITATIONS

    Cornices and eaves

    Not to exceed 2 ft.

    Sills, leaders, belt courses, and similar ornamental or structural features

    Not to exceed 6 in.

    The ordinary projection of skylights, above the bottom of the minimum side setback

    Shall be placed so as not to obstruct light and ventilation

    Awnings serving a window, porch, or door

    Not to exceed 40 in.

    A chimney, smokestack, or flue

    Not to exceed 2 ft.

    A self-contained air conditioner

    Not to exceed 2 ft.

    Building components or appurtenances dedicated to the environmental sustainability of the building

    Not to exceed 4 ft.

    A structure, including a building

    Must be less than 4 ft. in height above the grade at any point.

    Any railing required by the D.C. Construction Codes Supplement, 12 DCMR, shall not be included in the measurement of the structure’s height.

    A fence or retaining wall

    Must be constructed in accordance with the  D.C. Construction Codes Supplement, 12 DCMR

    Stairs and associated D.C. Construction Code Supplement required guard rails

    Must lead to the first story of the building located entirely above grade, or to a story below grade

    An antenna

    Must comply with all other requirements of this title

     

     

     

authority

§ 1 of the Zoning Act of 1938, approved June 20, 1938 (52 Stat. 797, as amended; D.C. Official Code § 6-641.01 (2012 Repl.)).

source

Final Rulemaking published at 63 DCR 2447, 2650 (March 4, 2016 – Part 2).