Section 11-G202. COURTS  


Latest version.
  • 202.1 A court is not required in an MU zone, but where it is provided, it shall have the following minimum dimensions: 

     

    TABLE G § 202.1: MINIMUM COURT DIMENSIONS

     

    Type of Structure

    Minimum Width Open Court

    Minimum Width Closed Court

    Minimum Area Closed Court

    Residential, more than 3 units

    4 in./ft. of height of court;

     

    10 ft.  minimum

    4 in./ft. of height of court;

     

    15 ft. minimum

    Twice the square of the required width of court dimension;

    350 sq. ft. minimum

    Non-Residential and Lodging

    2.5 in./ft. of height of court;

     

    6 ft.  minimum

    2.5 in./ft. of height of court;

     

    12 ft. minimum

    Twice the square of the required width of court dimension;

    250 sq. ft. minimum

     

     

authority

§ 1 of the Zoning Act of 1938, approved June 20, 1938 (52 Stat. 797, as amended; D.C. Official Code § 6-641.01 (2012 Repl.)).

source

Final Rulemaking published at 63 DCR 2447, 2944 (March 4, 2016 – Part 2).