Section 11-K603. HEIGHT (STE)  


Latest version.
  • 603.1 The maximum permitted building height, not including the penthouse, as well as the maximum permitted penthouse height and number of stories, in the StE zones shall be given in the following table:

    TABLE K § 603.1:  MAXIMUM PERMITTED BUILDING HEIGHT, PENTHOUSE HEIGHT, AND PENTHOUSE STORIES

     

    Zone District

    Maximum Building Height (Feet.)

    Maximum Penthouse Height

    Maximum Penthouse Stories

    StE-1

    25

    12 ft. except

    15 ft. for penthouse mechanical space

    1;

    Second story permitted for penthouse mechanical space

    StE-2

     

    12 ft. except

    18 ft. 6 in. for penthouse mechanical space

    1;

    Second story permitted for penthouse mechanical space

    StE-3

    80

    20 ft.

    1;

    Second story permitted for penthouse mechanical space

    StE-4

    25

    12 ft. except

    15 ft. for penthouse mechanical space

    1;

    Second story permitted for penthouse mechanical space

    StE-5

    65

    12 ft. except

    18 ft. 6 in. for penthouse mechanical space

    1;

    Second story permitted for penthouse mechanical space

    StE-6

    90

    20 ft.

    1 plus mezzanine;

    Second story permitted for penthouse mechanical space

    StE-7

    Subtitle K § 603.2

    Subtitle K § 603.2

    Subtitle K § 603.2

    StE-8

    25

    12 ft. except

    15 ft. for penthouse mechanical space

    1;

    Second story permitted for penthouse mechanical space

    StE-9

    65

    12 ft. except

    18 ft. 6 in. for penthouse mechanical space

    1;

    Second story permitted for penthouse mechanical space

    StE-10

    40

    12 ft. except

    15 ft. for penthouse mechanical space

    1;

    Second story permitted for penthouse mechanical space

    StE-11

    25

    12 ft. except

    15 ft. for penthouse mechanical space

    1;

    Second story permitted for penthouse mechanical space

    StE-12

    80

    20 ft.

    1;

    Second story permitted for penthouse mechanical space

    StE-13

    90

    20 ft.

    1 plus mezzanine;

    Second story permitted for penthouse mechanical space

    StE-14    A & B

    40

    12 ft. except

    15 ft. for penthouse mechanical space

    1;

    Second story permitted for penthouse mechanical space

    StE-15

    80

    20 ft.

    1;

    Second story permitted for penthouse mechanical space

    StE-16

    90

    20 ft.

    1 plus mezzanine;

    Second story permitted for penthouse mechanical space

    StE-17

    70

    20 ft.

    1;

    Second story permitted for penthouse mechanical space

    StE-18

    90

    20 ft.

    1 plus mezzanine;

    Second story permitted for penthouse mechanical space

    StE-19

    0

    0

    0

    603.2 Maximum permitted building height and penthouse height within the StE-7 zone is as follows:

    (a) For a distance of two-hundred fifty feet (250 ft.) measured from the north property line bounding Cypress Street, the maximum permitted building height, not including the penthouse, shall be eighty feet (80 ft.) and the maximum permitted height of the penthouse shall be twenty feet (20 ft.), and the maximum number of stories within the penthouse shall be one (1), except that a second story for penthouse mechanical space shall be permitted; and

    (b) For the remainder of this parcel, the maximum permitted height shall be fifty feet (50 ft.); and the maximum permitted height of a penthouse in the CG-5 zone shall be twelve feet (12 ft.), except that a height of fifteen feet (15 ft.) shall be permitted for penthouse mechanical space; and the maximum number of stories within the penthouse shall be one (1), except that a second story for penthouse mechanical space shall be permitted.

     

     

authority

§ 1 of the Zoning Act of 1938, approved June 20, 1938 (52 Stat. 797, as amended; D.C. Official Code § 6-641.01 (2012 Repl.)).

source

Final Rulemaking published at 63 DCR 2447, 3176 (March 4, 2016 – Part 2).