  • 807.1 A court is not required in an ARTS zone; however, if a court is provided it shall have the following minimum dimensions:

    TABLE K § 807.1:  MINIMUM COURT DIMENSIONS

     

    Type of Structure

    Minimum Width Open Court

    Minimum Width Closed Court

    Minimum Area Closed Court

    Residential, more than three units:

    4 in./ft. of height of court;

     

     

    10 ft. minimum

    4 in./ft. of height of court;

     

     

     

    15 ft. minimum

    Twice the square of the required width of court dimension;

     

    350 sq. ft. minimum

    Non-Residential and Lodging:

    2.5 in./ft. of height of court;

     

     

    6 ft. minimum

    2.5 in./ft. of height of court;

     

     

     

    12 ft. minimum

    Twice the square of the required width of court dimension;

     

    250 sq. ft. minimum

     

     