Strike the Exceptions to Section 806.1 of the International Green Construction Code in their entirety and insert new Exceptions to Section 806.1 in the Green Construction Code in their place to read as follows:
Exceptions:
1. Composite wood products that are made using adhesives that do not contain urea-formaldehyde (UF) resins.
2. Composite wood products that are sealed with an impermeable material on all sides and edges.
3. Composite wood products that are used to make elements considered to be furniture, fixtures and equipment (FF&E) that are not permanently installed.
4.Fire-retardant composite wood products.
Strike Section 806.2 of the International Green Construction Code in its entirety and insert new Section 806.2 in the Green Construction Code to read as follows:
806.2 Adhesives and sealants. Projects shall comply with the limits on volatile organic compound (“VOC”) emissions for adhesives and sealants as established in Chapter 7 (Volatile Organic Compounds and Hazardous Air Pollutants) of DCMR Title 20 (Environment).
Strike Section 806.3 of the International Green Construction Code in its entirety and insert new Section 806.3 in the Green Construction Code in its place to read as follows:
806.3 Architectural paints and coatings. Projects shall comply with the limits on volatile organic compound (“VOC”) emissions for architectural paints and coatings as established in Chapter 7 (Volatile Organic Compounds and Hazardous Air Pollutants) of DCMR Title 20 (Environment).