D.C. Municipal Regulations (Last Updated: September 13, 2017) |
Title 20. ENVIRONMENT |
Chapter 20-62. UNDERGROUND STORAGE TANKS - REPORTING OF RELEASES, INVESTIGATION, CONFIRMATION, ASSESSMENT AND CORRECTIVE ACTION |
Section 20-6208. TIER 0 STANDARDS
Latest version.
-
The Tier 0 standards for soil shall be the following:
(a)Total petroleum hydrocarbons (TPH) gasoline range organics (GRO) or diesel range organics (DRO) shall be no greater than one hundred parts per million (100 ppm);
(b)Total benzene, toluene, ethylbenzene, and total xylenes (BTEX) shall be no more than ten parts per million (10 ppm); and
(c)Benzene concentration shall be no more than one part per million (1 ppm).