Section 25-A1813. EQUIPMENT MANUAL AND MECHANICAL WAREWASHING, CHEMICAL SANITIZATION - TEMPERATURE, PH, CONCENTRATION, AND HARDNESS  


Latest version.
  •  

    1813.1A chemical sanitizer used in a sanitizing solution for a manual or mechanical operation at contact times specified in § 2002.2 shall meet the criteria specified in § 3404 Sanitizer, Criteria, shall be used in accordance with the EPA-registered label use instructions, and shall be used as specified in §§ 1813.2 through 1813.6. P

     

    1813.2A chlorine solution shall have a minimum temperature based on the concentration and pH of the solution as listed in the following chart: P

     

    Concentration

    Range

     

    Minimum Temperature

     

    mg/L

    pH 10 or less

    oC (oF)

    pH 8 or less

    oC (oF)

    25  - 49

    49 (120)

    49 (120)

    50 - 99

    38 (100)

    24 (75)

    100

    13 (55)

    13 (55)

     

    1813.3An iodine solution shall have a: 

     

    (a)Minimum temperature of twenty degrees Celsius (20o C) (sixty-eight  degrees Fahrenheit (68o F)); P

     

    (b)pH of  five (5.0) or less or a pH no higher than the level for which the  manufacturer specifies the solution is effective; P and

     

    (c)Concentration between twelve and a half micrograms per liter (12.5 mg/L)  and twenty-five micrograms per liter (25 mg/L). P

     

    1813.4A quaternary ammonium compound solution shall: 

     

    (a)Have a minimum temperature of twenty-four degrees Celsius (24o C)  (seventy-five degrees Fahrenheit (75o F)); P

     

    (b)Have a concentration as specified in § 3404 and as indicated by the  manufacturer's use directions included in the labeling; P and

     

    (c)Be used only in water with five hundred micrograms per liter (500 mg/L)  hardness or less, or in water having hardness no greater than specified by  the EPA-registered label use instructions. P

     

    1813.5If another solution of a chemical specified under §§ 1813.2 through 1813.4 is used, the licensee shall demonstrate to the Department that the solution achieves sanitization and the use of the solution shall be approved. P

     

    1813.6If a chemical sanitizer other than chlorine, iodine, or a quaternary ammonium compound is used, it shall be applied in accordance with the EPA-registered label use instructions. P 

     

authority

Sections 4 and 10 of An Act Relating to the adulteration of foods and drugs in the District of Columbia, approved February 17, 1898 (30 Stat. 246: D.C. Official Code §§ 48-104 and 48-110 (2009 Repl.)); Section 7 of An Act Making Appropriations to provide for the expenses for the government of the District of Columbia for the fiscal year ending June thirtieth, nineteen hundred and three, and for other purposes (32 Stat.627: D.C. Official Code § 47-2834(a)(1), (a)(2), and (b) (2005 Repl.)); and Mayor’s Order 98-139, dated August 20, 1998, and Mayor’s Order 2002-103, dated June 18, 2002.

source