4089343 D.C. Residential Code Supplement of 2013  

  • DEPARTMENT OF CONSUMER AND REGULATORY AFFAIRS
    CONSTRUCTION CODES COORDINATING BOARD

     

    NOTICE OF PROPOSED RULEMAKING

     

    The Chairperson of the Construction Codes Coordinating Board (Chairperson), pursuant to the authority set forth in section 10 of the Construction Codes Approval and Amendments Act of 1986 (Act), effective March 21, 1987 (D.C. Law 6-216; D.C. Official Code § 6-1409 (2008 Repl.)) and Mayor’s Order 2009-22, dated February 25, 2009, as amended, hereby gives notice of the intent to adopt the following amendments to Title 12 (D.C. Construction Codes Supplement of 2008) of the District of Columbia Municipal Regulations, as well as to rename Title 12.

     

    This proposed rulemaking would adopt the following codes published by the International Code Council (ICC), as amended by this rulemaking in a new District of Columbia Construction Codes Supplement of 2013, as the District of Columbia Construction Codes: the 2012 edition of the International Building Code; the 2012 edition of the International Residential Code; the 2012 edition of the International Fuel Gas Code; the 2012 edition of the International Mechanical Code; the 2012 edition of the International Plumbing Code; the 2012 edition of the International Property Maintenance Code; the 2012 edition of the International Fire Code; the 2012 edition of the  International Energy Conservation Code; the 2012 edition of the International Existing Building Code; the 2012 edition of the International Green Construction Code; the 2012 edition of the International Swimming Pool and Spa Code; and the 2011 edition of the National Electrical Code (NFPA 70) published by the National Fire Protection Association.

     

    This proposed rulemaking would repeal the D.C. Construction Codes Supplement of 2008, adopted December 26, 2008 (55 DCR 13094), consisting of the following: the 2006 edition of the ICC International Building Code; the 2006 edition of the ICC International Residential Code; the 2006 edition of the ICC International Fuel Gas Code; the 2006 edition of the ICC International Mechanical Code; the 2006 edition of the ICC International Plumbing Code; the 2006 edition of the ICC International Property Maintenance Code; the 2006 edition of the ICC International Fire Code; the 2006 edition of the ICC International Energy Conservation Code; the 2006 edition of the ICC International Existing Building Code; and the 2005 edition of the National Fire Protection Association (NFPA 70) National Electrical Code.

     

    Comments on this proposed rulemaking must be submitted by 5 p.m. on Friday, January 25, 2013. The process for submitting comments is detailed on the final page of this proposed rulemaking.

     

    The Chairperson also hereby gives notice of the intent to take final rulemaking action to adopt this amendment.  Pursuant to section 10(a) of the Act, the proposed amendment will be submitted to the Council of the District of Columbia for a forty-five (45) day period of review, and final rulemaking action will not be taken until the later of thirty (30) days after the date of publication of this notice in the D.C. Register or Council approval of the amendment.

     

    Title 12 (D.C. Construction Codes Supplement of 2008) of the District of Columbia Municipal Regulations is amended as follows:

     

    The title of title 12 is renamed as the District of Columbia Construction Codes Supplement of 2013.

     

    Subtitle 12 A (Building Code Supplement of 2008) is repealed in its entirety and replaced with a new Building Code Supplement of 2013.

     

    Subtitle 12 B (Residential Code Supplement of 2008) is repealed in its entirety and replaced with a new Residential Code Supplement of 2013.

     

    Subtitle 12 C (Electrical Code Supplement of 2008) is repealed in its entirety and replaced with a new Electrical Code Supplement of 2013.

     

    Subtitle 12 D (Fuel Gas Code Supplement of 2008) is repealed in its entirety and replaced with a new Fuel Gas Code Supplement of 2013.

     

    Subtitle 12 E (Mechanical Code Supplement of 2008) is repealed in its entirety and replaced with a new Mechanical Code Supplement of 2013.

     

    Subtitle 12 F (Plumbing Code Supplement of 2008) is repealed in its entirety and replaced with a new Plumbing Code Supplement of 2013.

     

    Subtitle 12 G (Property Maintenance Code Supplement of 2008) is repealed in its entirety and replaced with a new Property Maintenance Code Supplement of 2013.

     

    Subtitle 12 H (Fire Code Supplement of 2008) is repealed in its entirety and replaced with a new Fire Code Supplement of 2013.

     

    Subtitle 12 I (Energy Conservation Code Supplement of 2008) is repealed in its entirety and replaced with a new Energy Conservation Code Supplement of 2013.

     

    Subtitle 12 J (Existing Building Supplement of 2008) is repealed in its entirety and replaced with a new Existing Building Code Supplement of 2013.

     

    Subtitle 12 K (Fees) is redesignated as Subtitle M (Fees).

     

    A new Subtitle 12 K (Green Construction Code Supplement of 2013) is added.

     

    A new Subtitle 12 L (Swimming Pool and Spa Code Supplement of 2013) is added.

     

    For purposes of clarity, the following table lists each chapter of the ICC and NFPA 70 codes amended by the District of Columbia Construction Codes Supplement of 2013:

     

    Subtitle A – Building Code Supplement

     

    Chapter 1        Administration and Enforcement

    Chapter 2        Definitions

    Chapter 3        Use Group and Classification

    Chapter 4        Special Detailed Requirements Based on Use and Occupancy

    Chapter 5        General Building Heights and Areas

    Chapter 7        Fire-Resistance-Related Construction

    Chapter 9        Fire Protection Systems

    Chapter 10      Means of Egress

    Chapter 12      Interior Environment

    Chapter 14      Exterior Walls

    Chapter 15      Roof Assemblies and Rooftop Structures

    Chapter 16      Structural Design

    Chapter 18      Soils and Foundations

    Chapter 26      Plastic

    Chapter 30      Elevators and Conveying Systems

    Chapter 31      Special Construction

    Chapter 32      Encroachments into the Public Right-of-Way

    Chapter 33      Safeguards During Construction

    Chapter 34      Existing Structures

    Chapter 35      Referenced Standards

    Appendix E     Supplementary Accessibility Requirements

     

    Subtitle B – Residential Code Supplement

     

    Chapter 1        Scope and Administration

    Chapter 2        Definitions

    Chapter 3        Building Planning

    Chapter 9        Roof Assemblies

    Chapter 11      Energy Efficiency

    Chapter 12      Mechanical Administration

    Chapter 15      Exhaust Systems

    Chapter 16      Duct Systems

    Chapter 24      Fuel Gas

    Chapter 25      Plumbing Administration

    Chapter 29      Water Supply and Distribution

    Chapter 30      Sanitary Drainage

    Chapter 44      Referenced Standards

    Appendix H    Patio Covers

    Appendix J      Existing Buildings and Structures

    Appendix K    Sound Transmission

    Appendix M    Home Day Care – R-3 Occupancies

     

    Subtitle C – Electrical Code Supplement

     

    Article 90        Introduction

    Article 408      Switchboards and Panelboards

     

    Subtitle D – Fuel Gas Code Supplement

     

    Chapter 1        Scope and Administration

    Chapter 2        Definitions

    Chapter 5        Chimneys and Vents

    Chapter 8        Referenced Standards

     

    Subtitle E – Mechanical Code Supplement

     

    Chapter 1        Scope and Administration

    Chapter 2        Definitions

    Chapter 4        Ventilation

    Chapter 5        Exhaust Systems

    Chapter 6        Duct Systems

    Chapter 8        Chimneys and Vents

    Chapter 9        Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment

    Chapter 10      Boilers, Water Heaters and Pressure Vessels

    Chapter 11      Refrigeration

    Chapter 15      Referenced Standards

     

    Subtitle F – Plumbing Code Supplement

     

    Chapter 1        Scope and Administration

    Chapter 3        General Regulations

    Chapter 4        Fixtures, Faucets and Fixture Fittings

    Chapter 6        Water Supply and Distribution

    Chapter 8        Indirect/Special Waste

    Chapter 11      Storm Drainage

    Chapter 13      Nonliquid Saturated Treatment Systems

     

    Subtitle G – Property Maintenance Code Supplement

     

    Chapter 1        Administration and Enforcement

    Chapter 2        Definitions

    Chapter 3        Requirements

    Chapter 4        Light, Ventilation and Occupancy Limitations

    Chapter 5        Plumbing Facilities and Fixture Requirements

    Chapter 6        Mechanical and Electrical Requirements

    Chapter 7        Fire Safety Requirements

    Chapter 8        Referenced Standards

     

    Subtitle H – Fire Code Supplement

     

    Chapter 1        Administration and Enforcement

    Chapter 2        Definitions

    Chapter 3        General Requirements

    Chapter 5        Fire Service Features

    Chapter 6        Building Services and Systems

    Chapter 9        Fire Protection Systems

    Chapter 10      Means of Egress

    Chapter 11      Construction Requirements for Existing Buildings

    Chapter 56      Explosives and Fireworks

    Appendix B    Fire-Flow Requirements for Buildings

    Appendix C    Fire Hydrant Locations and Distribution

    Appendix D    Fire Apparatus Access Roads

    Appendix H    Hazardous Materials Management Plan (HMMP) and Hazardous Materials Inventory Statement (HMIS) Instructions

     

    Subtitle I – Energy Conservation Code Supplement

     

    Chapter 1[CE] Administration

    Chapter 4[CE] Commercial Energy Efficiency

    Chapter 1[RE] Scope and Administration

     

    Subtitle J – Existing Building Code Supplement

     

    Chapter 1        Scope and Administration

    Chapter 2        Definitions

    Chapter 4        Prescriptive Compliance Method

    Chapter 6        Repairs

    Chapter 7        Alterations-Level 1

    Chapter 8        Alterations-Level 2

    Chapter 9        Alterations-Level 3

    Chapter 10      Change of Occupancy

    Chapter 15      Construction Safeguards

     

    Subtitle K – Green Construction Code

     

    Chapter 1        Scope and Administration

    Chapter 2        Definitions

    Chapter 3        Green Building Act and ASHRAE 189.1

    Chapter 4        Site Development and Land Use

    Chapter 5        Material Resource Conservation and Efficiency

    Chapter 6        Energy Conservation, Efficiency, and CO2e  

    Chapter 7        Water Resource Conservation, Quality and Efficiency

    Chapter 8        Indoor Environmental Quality and Comfort

    Chapter 9        Commissioning

    Chapter 10      Existing Buildings

    Chapter 11      Existing Building Site Development

    Chapter 12      Referenced Standards

    Appendix A    Project Electives

     

    Subtitle L – Swimming Pool and Spa Code Supplement

     

    Chapter 1        Scope and Administration

    Chapter 2        Definitions


    DISTRICT OF COLUMBIA

    CONSTRUCTION CODES SUPPLEMENT OF 2013

    12 DCMR B RESIDENTIAL CODE SUPPLEMENT

     

     

    The District of Columbia has adopted the 2012 edition of the International Residential Code (IRC), as amended by this Supplement.

     

    IRC CHAPTERS AMENDED BY THIS SUPPLEMENT:

     

    CHAPTER 1         SCOPE AND ADMINISTRATION

    CHAPTER 2         DEFINITIONS

    CHAPTER 3         BUILDING PLANNING

    CHAPTER 9         ROOF ASSEMBLIES

    CHAPTER 11       ENERGY EFFICIENCY

    CHAPTER 12       MECHANICAL ADMINISTRATION

    CHAPTER 15       EXHAUST SYSTEMS

    CHAPTER 16       DUCT SYSTEMS

    CHAPTER 24       FUEL GAS

    CHAPTER 25       PLUMBING ADMINISTRATION

    CHAPTER 29       WATER SUPPLY AND DISTRIBUTION

    CHAPTER 30       SANITARY DRAINAGE

    CHAPTER 44       REFERENCED STANDARDS

    APPENDIX H      PATIO COVERS

    APPENDIX J       EXISTING BUILDINGS AND STRUCTURES

    APPENDIX K      SOUND TRANSMISSION

    APPENDIX M     HOME DAY CARE – R-3 OCCUPANCIES

     


    Strike Chapter 1 of the International Residential Code in its entirety and insert new Chapter 1 in the Residential Code in its place to read as follows:

     

    CHAPTER 1             SCOPE AND ADMINISTRATION

     

    R101   General

     

     

    R101   GENERAL

     

    R101.1 General.  Administration and enforcement of the Residential Code shall be governed by Chapter 1 of the Building Code, 12 DCMR A.

     


    CHAPTER 2             DEFINITIONS

     

    R202   Definitions

     

     

    R202   DEFINITIONS

     

    Strike the definition of Third Party Certified in Section R202 of the International Residential Code in its entirety and insert a new definition of Third Party Certified in the Residential Code in its place to read as follows:

     

    THIRD PARTY CERTIFIED.  Product or material for which a certification was obtained by the manufacturer indicating that the function and performance characteristics of such product or material have been determined by testing and ongoing surveillance by an approved third-party certification agency.  Assertion of certification is in the form of identification in accordance with the requirements of the third-party certification agency.

     

    Strike the definition of Third Party Tested in Section R202 of the International Residential Code in its entirety and insert a new definition of Third Party Tested in the Residential Code in its place to read as follows:

     

    THIRD PARTY TESTED.  Product, material or system that has undergone successfully a procedure by which an approved testing laboratory provides documentation that such product, material or system conforms to specified requirements.

     


    CHAPTER 3             BUILDING PLANNING

     

    R301   Design Criteria

    R319   Site Address

     

    R301   DESIGN CRITERIA

     

    Strike Table R301.2(1), Climatic and Geographic Design Criteria, in the International Residential Code in its entirety and insert new Table R301.2(1) in the Residential Code in its place to read as follows:

     

    TABLE R301.2(1)
    CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA

    GROUND

    SNOW LOAD

    WIND DESIGN

    SEISMIC DESIGN CATEGORYf

    SUBJECT TO DAMAGE FROM

    WINTER DESIGN TEMPe

    ICE BARRIER UNDERLAY-MENT REQUIREDh

    FLOOD HAZARDSg

    AIR FREEZING

    INDEXi

     

    Speedd (mph)

    Topographic

    effectsk

    Weatheringa

    Frost line depthb

    Termitec

    MEAN ANNUAL TEMPj

    25 

    90

    Na

    A

    M

    30

    M-H

    17

    N

    (a) November 15, 1985.

    (b) November 15, 1985; September 27, 2010.

    (c) All current FIRMs dated 09/27/2010; Panel numbers 110001IND0A, 1100010002C, 1100010003C, 1100010004C, 1100010006C, 1100010008C, 1100010011C, 1100010012C, 1100010014C, 1100010016C, 1100010018C, 1100010019C, 1100010036C, 1100010037C, 1100010038C, 1100010039C, 1100010041C, 1100010043C, 1100010056C, 1100010057C, 1100010058C, 1100010059C, 1100010066C, 1100010067C, 1100010076C, 1100010077C and 1100010078C.

    500

     

     

     

     

     

     

     

     

     

     

     

    55

     

    For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s.

    a. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code.  The weathering column shall be filled in with the weathering index (i.e., “negligible,” “moderate” or “severe”) for concrete as determined from the Weathering Probability Map [Figure R301.2(3)].  The grade of masonry units shall be determined from ASTM C 34, C 55, C 62, C 73, C 90, C 129, C 145, C 216 or C 652.

    b. The frost line depth may require deeper footings than indicated in Figure R403.1(1).  The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade.

    c. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage.

    d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map [Figure R301.2(4)A].  Wind exposure category shall be determined on a site-specific basis in accordance with Section R301.2.1.4.

    e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the International Plumbing Code.  Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official.

    f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1.

    g. The jurisdiction shall fill in this part of the table with (a) the date of the jurisdiction’s entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas), (b) the date(s) of the Flood Insurance Study and (c) the panel numbers and dates of all currently effective FIRMs and FBFMs or other flood hazard map adopted by the authority having jurisdiction, as amended.

    h. In accordance with Sections R905.2.7.1, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with “YES.”  Otherwise, the jurisdiction shall fill in this part of the table with “NO.”

    i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF-days) from Figure R403.3(2) or from the 100-year (99 percent ) value on the National Climatic Data Center data table “Air Freezing Index-USA Method (Base 32 °F)” at www.ncdc.noaa.gov/fpsf.html.

    j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table “Air Freezing Index-USA Method (Base 32 °F)” at www.ncdc.noaa.gov/fpsf.html.

    k. In accordance with Section R301.2.1.5, where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects, the jurisdiction shall fill in this part of the table with “YES.”  Otherwise, the jurisdiction shall indicate “NO” in this part of the table.

     

    Strike Section R319, Site Address, in the International Residential Code in its entirety and insert new Section R319 in the Residential Code to read as follows:

     

    R319   SITE ADDRESS

     

    R319.1 Address Numbers.  Premises shall comply with the provisions set forth in Section 118, 12 DCMR A, governing street numbering and addresses.

     


    CHAPTER 9             ROOF ASSEMBLIES

     

    R908   Cool Roof Requirements

     

    Insert new Section R908 in the Residential Code to read as follows:

     

    R908   COOL ROOF REQUIREMENTS

     

    R908.1 General.  Roof coverings for roof slopes less than or equal to two units vertical in 12 units horizontal (17 percent slope or less) for buildings and covered parking shall conform to this section.  A minimum of 75 percent of the entire roof surface not used for roof penetrations, renewable energy power systems (e.g., photovoltaics or solar thermal collectors), harvesting systems for rainwater to be used on-site, or green roofing systems shall be covered with products that comply with one or more of the following:

     

    1.         Have a minimum three-year-aged Solar Reflective Index (SRI) of 64.

     

    2.         Comply with the criteria for roof products as defined in “ENERGY STAR® Program Requirements, Product Specification for Roof Products, Eligibility Criteria.”

     

    Exceptions:

     

    1.      Building projects where an annual energy analysis simulation demonstrates that the total annual building energy consumption with the proposed roof is 2 percent less than it would be with a roof having a three-year-aged SRI of 64.

     

    2.      Roofs used to shade or cover parking and roofs over semi-heated spaces or used as outdoor recreation space by the occupants of the building shall be permitted to be either landscaped or have a minimum initial SRI of 29.  A default SRI value of 35 for new concrete without added color pigment is allowed to be used in lieu of measurements.

     

    3.      Terraces on setbacks comprising less than 25 percent of the area of the largest floor plate in the building.

     

    4.      Green roofs shall be permitted to comprise part or all of the 75 percent

             required area coverage.

     

    R908.2 Solar Reflective Index.  Initial and aged values of the SRI shall be calculated in accordance with ASTM E1980 for medium-speed wind conditions, using a convection coefficient of [2.1 BTU/(h ∙ ft2 ∙ °F)] or the metric equivalent [12 W/(m2 ∙ K)].  The SRI shall be based upon solar reflectance as measured in accordance with ASTM E1918 or ASTM C1549, and the thermal emittance as measured in accordance with ASTM E408 or ASTM C1371.  For roofing products, the values for solar reflectance and thermal emittance shall be determined by a laboratory accredited by a nationally recognized accreditation organization, such as the Cool Roof Rating Council CRRC-1 Product Rating Program, and shall be labeled and certified by the manufacturer.

     


    Strike Chapter 11, Energy Efficiency, of the International Residential Code in its entirety and insert new Chapter 11 in the Residential Code in its place to read as follows:

     

    CHAPTER 11           ENERGY EFFICIENCY

     

    1101.1  General. Building projects shall comply with the Energy Conservation Code.

     

     


    Strike Chapter 12 of the International Residential Code in its entirety and insert new Chapter 12 in the Residential Code in its place to read as follows:

     

    CHAPTER 12           MECHANICAL ADMINISTRATION

     

    M1201 General

     

     

    M1201 GENERAL

     

    M1201.1 General.  Administration and enforcement of Part V – Mechanical of the Residential Code shall be governed by Chapter 1 of the Building Code, 12 DCMR A.

     


    CHAPTER 15           EXHAUST SYSTEMS

     

    M1502 Clothes Dryer Exhaust

     

     

    M1502 CLOTHES DRYER EXHAUST

     

    Strike Section M1502.4.2 of the International Residential Code in its entirety and insert new Section M1502.4.2 in the Residential Code in its place to read as follows:

     

    M1502.4.2 Duct installation.  Exhaust ducts shall be supported at intervals not to exceed 4 feet (1219 mm) and shall be secured in place.  The insert end of the duct shall extend into the adjoining duct or fitting in the direction of airflow.  Exhaust duct joints shall be sealed in accordance with Section M1601.4.1 and shall be mechanically fastened.  Ducts shall not be joined with screws or similar fasteners that protrude more than 1/8 inch (3.2 mm) into the inside of the duct.


    CHAPTER 16           DUCT SYSTEMS

     

    M1601 Duct Construction

     

     

    M1601 DUCT CONSTRUCTION

     

    Strike Section M1601.1.1 of the International Residential Code in its entirety and insert new Section M1601.1.1 in the Residential Code in its place to read as follows:

     

    M1601.1.1 Above-ground duct systems.  Above-ground duct systems shall conform to the following:

     

    1.   Equipment connected to duct systems shall be designed to limit discharge air temperature to a maximum of 250ºF (121ºC).

     

    2.   Factory-made air ducts shall be constructed of Class 0 or Class 1 materials as designated in Table M1601.1.1(1).

     

    3.   Fibrous duct construction shall conform to the SMACNA Fibrous Glass Duct Construction Standards or NAIMA Fibrous Glass Duct Construction Standards.

     

    4.   Minimum thickness of metal duct material shall be as listed in table M1601.1.1(2). Galvanized steel shall conform to ASTM A653. Metallic ducts shall be fabricated in accordance with SMACNA HVAC Duct Construction Standards – Metal and Flexible.

     

    5.   Use of gypsum products to construct return air ducts or plenums is permitted, provided that the air temperature does not exceed 125ºF (52ºC) and exposed surfaces are not exposed to condensation.

     

    6.   Duct systems shall be constructed of materials having a flame spread index not greater than 200.

     

    7.   Stud wall cavities and the spaces between solid floor joists to be used as air plenums shall comply with the following conditions:

     

    7.1.      These cavities or spaces shall not be used as a plenum for supply air.

     

    7.2.      These cavities or spaces shall not be part of a required fire-resistance-rated assembly.

     

    7.3.      Stud wall cavities shall not convey air from more than one floor level.

     

    7.4.      Stud wall cavities and joist-stud plenums shall be isolated from adjacent concealed spaces by tight-fitting fireblocking in accordance with Section R602.8.

     

    7.5.      Stud wall cavities in the outside walls of building envelope assemblies shall not be utilized as air plenums.

     

    Strike Section M1601.4.1 of the International Residential Code in its entirety and insert new Section M1601.4.1 in the Residential Code in its place to read as follows:

     

    M1601.4.1 Joints, seams and connections.  All longitudinal joints, seams and connections in metallic and nonmetallic ducts shall be constructed as specified in SMACNA HVAC Duct Construction Standards – Metal and Flexible and NAIMA Fibrous Glass Duct Construction Standards.  All joints, longitudinal and transverse seams, and connections in ductwork shall be securely fastened and sealed with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric systems, liquid sealants or tapes.

     

    Closure systems used to seal flexible air ducts and flexible air connectors shall comply with UL 181B and shall be marked “181 B-FX” for pressure-sensitive tape or “181 B-M” for mastic.  Duct connections to flanges of air distribution system equipment shall be sealed and mechanically fastened.  Mechanical fasteners for use with flexible non-metallic air ducts shall comply with UL 181B and shall be marked “181 B-C.”  Crimp joints for round metallic ducts shall have a contact lap of not less than 1 inch (25.4 mm) and shall be mechanically fastened by means of not less than three sheet-metal screws or rivets equally spaced around the joint.

     

    Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer’s instructions.  Round metallic ducts shall be mechanically fastened by means of at least three sheet-metal screws or rivets spaced equally around the joint. Unlisted duct tape shall not be permitted as a sealant on any duct.

     

    Exceptions:

     

    1.            Spray polyurethane foam shall be permitted to be applied without additional joint seals.

     

    2.            Where a duct connection is made that is partially inaccessible, three screws or rivets shall be equally spaced on the exposed portion of the joint so as to prevent a hinge effect.

     

    3.            Continuously welded and locking-type longitudinal joints and seams in ducts operating at static pressures less than 2 inches of water column (500 Pa) pressure classification shall not require additional closure systems.

     


    CHAPTER 24           FUEL GAS

     

    G2401 General

     

     

    G2401 GENERAL

     

    Strike Section G2401.1 of the International Residential Code in its entirety and insert new Section G2401.1 in the Residential Code in its place to read as follows:

     

    G2401.1 General.  Administration and enforcement of Part VI – Fuel Gas of the Residential Code shall be governed by Chapter 1 of the Building Code, 12 DCMR A.

     


    Strike Chapter 25 of the International Residential Code in its entirety and insert new Chapter 25 to the Residential Code in its place to read as follows:

     

    CHAPTER 25           PLUMBING ADMINISTRATION

     

    P2501  General

     

     

    P2501  GENERAL

     

    P2501.1 General.  Administration and enforcement of Part VII – Plumbing of the Residential Code shall be governed by Chapter 1 of the Building Code, 12 DCMR A.


    CHAPTER 29           WATER SUPPLY AND DISTRIBUTION

     

    P2902  Protection of Potable Water Supply

    P2903  Water-Supply System

    P2908  Drinking Water Treatment Units

     

     

    P2902  PROTECTION OF POTABLE WATER SUPPLY

     

    Strike Section P2902.5.4 of the International Residential Code in its entirety and insert new Section P2902.5.4 in the Residential Code in its place to read as follows:

     

    P2902.5.4 Connections to automatic fire sprinkler systems.  The potable water supply to automatic fire sprinkler systems shall be protected against backflow by a double check backflow prevention assembly, a double check fire protection backflow prevention assembly, a reduced pressure principle backflow prevention assembly or a reduced pressure principle fire protection backflow prevention assembly.

     

    Exception:  Where systems are installed as a portion of the water distribution system in accordance with the requirements of this code and are not provided with a fire department connection, backflow protection for the water supply system shall not be required.

     

    Strike Section P2902.5.4.1 of the International Residential Code in its entirety and insert new Section P2902.5.4.1 in the Residential Code in its place to read as follows:

     

    P2902.5.4.1 Additives or nonpotable source.  Where systems under continuous pressure contain chemical additives or antifreeze, or where systems are connected to a nonpotable secondary water supply, the potable water supply shall be protected against backflow by a reduced pressure principle backflow prevention assembly or a reduced pressure principle fire protection backflow prevention assembly.  Where chemical additives or antifreeze are added to only a portion of an automatic fire sprinkler system, the reduced pressure principle backflow prevention assembly or the reduced pressure principle fire protection backflow prevention assembly may be located so as to isolate that portion of the system.  Where systems are not under continuous pressure, the potable water supply shall be protected against backflow by an air gap or an atmospheric vacuum breaker conforming to ASSE 1001 or CSA B64.1.1.

     

     

    P2903  WATER-SUPPLY SYSTEM

     

    Strike Table P2903.2 of the International Residential Code in its entirety and insert new Table P2903.2 in the Residential Code in its place to read as follows:

     

    TABLE P2903.2

    MAXIMUM FLOW RATES AND CONSUMPTION FOR

    PLUMBING FIXTURES AND FIXTURE FITTINGSb

     

    PLUMBING FIXTURE OR FIXTURE FITTING

    PLUMBING FIXTURE OR FIXTURE FITTING CONSUMPTION

    Lavatory faucet

    1.5 gpm at 60 psi

    Shower heada

    2.0 gpm at 80 psi

    Sink faucet

    1.5 gpm at 60 psi

    Water closetc

    1.28 gallons per flushing cycle

     

     

    For SI:  1 gallon per minute = 3.785 L/m,

                1 pound per square inch = 6.895 kPa

     

    a.  A handheld shower spray is also a shower head.

    b.  Consumption tolerances shall be determined from referenced standards.

    c.  Dual Flush Toilets - The effective flush volume shall not exceed 1.28 gallons (4.8 liters). The effective flush volume is defined as the composite, average flush volume of two reduced flushes and one full flush. Flush volumes will be tested in accordance with ASME A112.19.2 and ASME A112.19.14.

     

    P2908  DRINKING WATER TREATMENT UNITS

     

    Strike Section P2908.1 of the International Residential Code in its entirety and insert new Section P2908.1 in the Residential Code in its place to read as follows:

     

    P2908.1 Design.  Drinking water treatment units shall meet the requirements of NSF 42, NSF 44, NSF 53, NSF 62 or CSA B483.1.

     


    CHAPTER 30           SANITARY DRAINAGE

     

    P3005  Drainage System

     

     

    P3005  DRAINAGE SYSTEM

     

    Strike Section P3005.2 of the International Residential Code; do not strike Subsections P3005.2.1 through P3005.2.11 of the International Residential Code. Insert new Section P3005.2 in the Residential Code to read as follows:

     

    P3005.2 Drainage pipe cleanouts.  Drainage pipe cleanouts shall comply with Sections P3005.2.1 through P3005.2.12.

     

    Exception:  These provisions shall not apply to pressurized building drains and building sewers that convey the discharge of automatic pumping equipment to a gravity drainage system.

     

    Insert new Section P3005.2.12 in the Residential Code to read as follows:

     

    P3005.2.12 Cleanout at property line. A cleanout must be placed at the property line, or as close as possible to the property line, if the building wall is constructed on or beyond the property line.

     


    CHAPTER 44           REFERENCED STANDARDS

     

    ASME

    American Society of Mechanical Engineers

    Three Park Avenue

    New York, N.Y. 10016-5990

     

    Strike standard reference number ASME/A17.1-2007/CSA B44-200, and associated Title, from Chapter 44 of the International Residential Code, under subheading ASME, and insert in its place a new standard reference in the Residential Code to read as follows:

     

    Standard reference number

    Title

    Referenced in code section number

    A17.1-2010/

    CSA B44-2010               

    Safety Code for Elevators and Escalators

    R321.1

     

    Insert a new standard reference in Chapter 44 of the Residential Code to read as follows:

     

    ASTM

    ASTM International

    100 Barr Harbor

    West Conshohocken, PA 19428-2959

     

    Standard

    reference number

    Title

    Referenced in code section number

    E408-71 (2008)

     

    Standard Test Methods for Total Normal Emittance of Surfaces Using Inspection-Meter Techniques

     

    R908.2

    C1549-09

     

    Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer

    R908.2

    C 1371-04a

    Standard Test Method for Determination of Emittance of Materials Near Room Temperature Using Portable Emissometers

    R908.2

    E1980-11

     

    Standard Practice for Calculating Solar Reflectance Index of Horizontal and Low-Sloped Opaque Surfaces

    R908.2

    E1918-06

    Standard Test Method for Measuring Solar Reflectance of Horizontal and Low-Sloped Surfaces in the Field

    R908.2

     

    CSA

    Canadian Standards Association

    5060 Spectrum Way

    Mississauga, Ontario, Canada L4N 5N6

     

    Strike standard reference number ANSI/CSA America FCI-03, and associated Title, from Chapter 44 of the International Residential Code, under subheading CSA, and insert in its place a new standard reference in Chapter 44 of the Residential Code, under subheading CSA, to read as follows:

     

    Standard reference number

    Title

    Referenced in code section number

    ANSI/CSA America

    FC1–03

    Stationary Fuel Cell Power Systems

    M1903.1

     

    Insert a new standard reference in Chapter 44 of the Residential Code, under subheading CSA, to read as follows:

     

    Standard reference number

    Title

    Referenced in code section number

    B64.1.1–01

    Vacuum Breakers, Atmospheric Type (AVB)

    2902.5.4.1

     

    Insert the following new referenced standard in Chapter 44 of the Residential Code to read as follows:

     

    EPA

    Environmental Protection Agency

    Ariel Rios Building

    1200 Pennsylvania Avenue, NW

    Washington, D.C. 20460

     

    Standard

    reference number

    Title

    Referenced in code section number

    ENERGY STAR

    Energy Star Program Requirements, Product Specification for Roof Products, Eligibility Criteria, version 2.2 (October 2010)

    R908.1

    NSF

    NSF International

    789 N. Dixboro

    Ann Arbor, MI 48105

     

    Insert a new standard reference in Chapter 44 of the Residential Code, under subheading NSF, NSF International, to read as follows:

     

    Standard reference number

    Title

    Referenced in code section number

    62–2007

    Drinking Water Distillation Systems

    2908.1

     

    SMACNA

    Sheet Metal & Air Conditioning Contractors National Assoc., Inc.

    4021 Lafayette Center Road

    Chantilly, VA 22021

     

    Insert a new standard reference in Chapter 44 of the Residential Code, under the subheading SMACNA, Sheet Metal & Air Conditioning Contractors National Assoc., Inc. to read as follows:

     

    Standard reference number

    Title

    Referenced in code section number

    SMACNA/ANSI–2005

    HVAC Duct Construction Standards-Metal and Flexible (2005)

    M1601.1.1

     

    Strike standard reference number SMACNA-10, and associated Title, under subheading  SMACNA, Sheet Metal & Air Conditioning Contractors National Assoc., Inc. in Chapter 44 of the International Residential Code, and insert in Chapter 44 of the Residential Code in its place, under subheading SMACNA, Sheet Metal & Air Conditioning Contractors National Assoc., Inc.  a new standard reference, and associated Title, to read as follows:

     

    Standard reference number

    Title

    Referenced in code section number

    SMACNA 03

    Fibrous Glass Duct Construction Standards (2003)

    M1601.1.1, M1604.4.1


    APPENDIX H           PATIO COVERS

     

    Appendix H, Patio Covers, of the International Residential Code is adopted in its entirety as Appendix H of the Residential Code.


    APPENDIX J                        EXISTING BUILDINGS AND STRUCTURES

     

    Appendix J, Existing Building and Structures, of the International Residential Code is adopted as Appendix J of the Residential Code with the following amendments.

     

    AJ501  Alterations

     

     

    AJ501 ALTERATIONS

     

    Insert new Sections AJ501.8.4 and AJ501.8.5 in Appendix J of the Residential Code to read as follows:

     

    AJ501.8.4 Riser height. The maximum riser height of stairs being altered or modified shall be 8 ¼ inches (210 mm).  The riser shall be measured vertically between leading edges of the adjacent treads.  The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm).

     

    AJ501.8.5 Tread depth.  The minimum tread depth of stairs being altered or modified shall be 9 inches (229 mm).  The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the tread’s leading edge.  The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm).  The radius of curvature at the leading edge of the tread shall be no greater than 9/16 inch (14.3 mm).  A nosing not less than 3/4 inch (19.1 mm) but not more than 1 1/4 inches (32 mm) shall be provided on stairways with solid risers.  The greatest nosing projection shall not exceed the smallest nosing projection by more than 3/8 inch (9.5mm) between two stories, including the nosing at the level of floors and landings.  Beveling of nosing shall not exceed 1/2 inch (12.7 mm). Risers shall be vertical or sloped from the underside of the leading edge of the tread above at an angle not more than 30 degrees from the vertical.

     

    Exception:  A nosing is not required where the tread depth is a minimum of 11 inches (279 mm).

     


    APPENDIX K           SOUND TRANSMISSION

     

    Appendix K, Sound Transmission, of the International Residential Code is adopted in its entirety as Appendix K of the Residential Code.

     


    APPENDIX M          HOME DAY CARE R-3 OCCUPANCY

     

    Appendix M, Home Day Care R-3 Occupancy, of the International Residential Code is adopted in its entirety as Appendix M of the Residential Code.

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    All persons desiring to comment on these proposed regulations should submit comments in writing to Helder Gil, Legislative Affairs Specialist, Department of Consumer and Regulatory Affairs, 1100 Fourth Street, SW, Room 5164, Washington, D.C. 20024, or via e-mail at ConstructionCodes@dc.gov, not later than 5 p.m. on Friday, January 25, 2013.

     

    Comments should clearly specify which Subtitle, Chapter, and Section of the proposed District of Columbia Construction Codes they are related to.

     

    Persons with questions concerning this Notice of Proposed Rulemaking should call (202) 442-4400. Copies of the proposed rules can be obtained from the address listed above.  A copy fee of one dollar ($1.00) will be charged for each copy of the proposed rulemaking requested.

     

    Free copies of these proposed regulations are available on the DCRA website at http://dcra.dc.gov by going to the “About DCRA” tab, clicking on “News Room”, and then clicking on “Rulemaking”. Additionally, the DCRA website will list links to each of the ICC and NFPA 70 codes.